"LAZUR M-100". TECHNICAL DATA 
Quality of untreated water:
- general minerals content up to......................................................... 10 g/litre
- colour up to...................................................................................... 50 degrees
- temperature of water and ambient air..................................... from +4 0C to +30 0C
- content of non-spore-forming bacteria, (E-coli type) up to .......... 106 m.kl/litre
- content of dissolved oil-based products up ..................................... 2 mg/litre
- turbidity up to ................................................................................. 3 mg/litre
- iron not exceeding ........................................................................... 0.3 mg/litre
- content of spore-forming bacteria, (B-cereus) up to ........................ 105
Quality of treated water:
- colour up to ..................................................................................... 30 degrees
- content of non-spore-forming bacteria, (E-coli type) ....................... 0
- general number of microbes less than ............................................... 50
- content of spore-forming bacteria (B-cereus) ................................... 0
- content of dissolved oil-based products up ..................................... 0,05 mg/litre
Output ..................................................................................................... 100 ì3/hour
Power consumption less than ..................................................................... 3500 W
Power source (AC) nominal 220 V ± 5%, 50 Hz
Level of Protection for Power Supply Unit IP55
Ultraviolet radiation of not less than ..................................................... 40 mJ/cm2
Lamp Service Life (operating hours) not less than ....................................... 9000 hours
Time before ready for operation not more than ………………................... 1 sec

|