"LAZUR M-1". TECHNICAL DATA 
Quality of untreated water:
- general minerals content up to ............................................................... 1 g/litre
- colour up to ............................................................................................ 50 degrees
- temperature of water and ambient air .................................................... from +4 0C to +30 0C
- content of non-spore-forming bacteria, (E-coli type) up to ............... 106 m.kl/litre
- content of dissolved oil-based products up ....................................... 1 mg/litre
- turbidity up to .................................................................................... 3 mg/litre
- iron not exceeding ............................................................................. 0.3 mg/litre
- content of spore-forming bacteria, (B-cereus) up to ........................... 105
Quality of treated water:
- colour up to .......................................................................................... 30 degrees
- content of non-spore-forming bacteria, (E-coli type) ....................... 0
- general number of microbes less than .............................................. 50
- content of spore-forming bacteria (B-cereus) ................................... 0
- content of dissolved oil-based products up .................................. 0,05 mg/litre
Output ...................................................................................................... 1000 litre/hour
Power consumption less than ....................................................................... 20 W
Power source (AC) nominal 220 V ± 5%, 50 Hz
Level of Protection for Power Supply Unit IP55
Ultraviolet radiation of not less than .......................................................... 40 mJ/cm2
Lamp Service Life (operating hours) not less than .................................. 9000 hours
Time before ready for operation not more than
................. 1 sec
A |
Α (μμ) |
G 2 |
170 |
G 1 |
200 |

|